AV-14A3
AV-1415EE
AV-14AMG3
Measuring
ItemTest pointAdjustment partDescription
instrument
AdjustmentRemote3. BRIGHT1.R eceive any broadcast.
control unit
of2.En ter the SERVICE MENU.
SUB BRIGHT3.S elect 2. V/C from SERVICE MENU.
4.S elect 3. BRIGHT with the MENU 1/2key.
5.S et the initial setting value with the MENU - / + key.
6.I f the brightness is not the best with the initial set value, make
fine adjustment until you get the best brightness.
AdjustmentRemote4. CONT.1.R eceive any broadcast.
control unit
of2.En ter the SERVICE MENU.
SUB CONT.3.S elect 2. V/C from SERVICE MENU.
4.S elect 4. CONT. with the MENU 1/2key.
5.S et the initial setting value with the MENU - / + key.
6.If the contrast is not the best with the initial set value, make fine
adjustment until you get the best contrast.
AdjustmentRemote5. COLOUR[Method of adjustment without measuring instrument]
control unit
of
SUB
COLOUR ````PAL COLOUR1.R eceive a PAL broadcast.
2.En ter the SERVICE MENU.
3.S elect 2. V/C from the SERVICE MENU.
4.S elect 5. COLOUR with the MENU 1/2 key.
5.S et the initial setting value for PAL COLOUR with the MENU
- / + key.
6.I f the colour is not the best with the initial set value, make fine
adjustment until you get the best colour.
SECAM COLOUR1.R eceive a SECAM broadcast.
2.M ake fine adjustment of SECAM COLOUR as previously.
NTSC 3.58 COLOUR1.R eceive a NTSC 3.58MHz broadcast.
2.M ake similar fine adjustment of NTSC 3.58 COLOUR as
previously.
NTSC 4.43 COLOURWhen NTSC 3.58 adjustment completed, NTSC 4.43 will be
automatically set at the respective values.
No. 5202923 |