AV-14AM
Measuring
ItemTest pointAdjustment partDescription
instrument
AdjustmentRemote3. BRIGHT1. Receive any broadcast.
control unit
of2. Select 2. V/C from SERVICE MENU.
SUB3. Select 3. BRIGHT with the MENU 1/2key.
BRIGHT4. Set the initial setting value with the MENU - or + key.
5. If the brightness is not the best with the initial set value, make
fine adjustment until you get the best brightness.
AdjustmentRemote4. CONT.1. Receive any broadcast.
control unit
of2. Select 2. V/C from SERVICE MENU.
SUB CONT.3. Select 4. CONT. with the MENU 1/2key.
4. Set the initial setting value with the MENU - or + key.
5. If the contrast is not the best with the initial set value, make fine
adjustment until you get the best contrast.
AdjustmentRemote5. COLOUR[Method of adjustment without measuring instrument]
control unit
of
SUB
COLOUR ````PAL COLOUR1. Receive a PAL broadcast.
2. Select 2. V/C from the SERVICE MENU.
3. Select 5. COLOUR with the MENU 1/2 key.
4. Set the initial setting value for PAL COLOUR with the MENU -
or + key.
5. If the colour is not the best with the initial set value, make fine
adjustment until you get the best colour.
SECAM COLOUR1. Receive a SECAM broadcast.
2. Make fine adjustment of SECAM COLOUR as previously.
NTSC 3.58 COLOUR1. Receive a NTSC 3.58MHz broadcast.
2. Make similar fine adjustment of NTSC 3.58 COLOUR as
previously.
NTSC 4.43 COLOURWhen NTSC 3.58 adjustment completed, NTSC 4.43 will be
automatically set at the respective values.
No. 5609119 |