AV-14AMG3
Measuring
ItemTest pointAdjustment partDescription
instrument
AdjustmentSignal4. VER. LIN.IIII When the vertical linearity has been deteriorated
generator
of VER. LIN.5. VER. SCURVEremarkably, perform the following steps.
& VER.
Remote
15. Input a cross-hatch signal.
SCURVEcontrol unit
16. Select 4. VER. LIN. with the MENU 1/2 key.
17. Set the initial setting value of 4. VER LIN. with the MENU - / +
key.
TOP18. Select 5. VER. SCURVE with the MENU 1/2 key.
19. Set the initial setting value of 5. VER. SCURVE with the MENU
- / + key.
20. Adjust 4. VER. LIN. and 5. VER. SCURVE so that the spaces
CENTER
of each line as shown in Fig.3 on TOP, CENTER and
BOTTOM become uniform.
BOTTOM
Make sure that the adjustment is properly done on the screen of
60Hz mode.
Fig.3
[NOTE]
" Adjust to make both 50Hz & 60Hz are the same v. size and
fine straight line.
" When adjust again, adjust 50Hz mode first.
" When adjust in 60Hz mode, only 60Hz mode is adjust.
VSM PRESET SETTING
Measuring
ItemTest pointAdjustment partDescription
instrument
Setting ofRemoteTINT1. Enter the SERVICE MENU.
VSMcontrol unitCOLOUR2. Select 4. VSM PRESET from the SERVICE MENU.
PRESETBRIGHT3. Select BRIGHT with the PICTURE MODE key.
CONT.4. Adjust the MENU 1/2 and MENU - / + key to bring the set
SHARPvalues of TINT ^^^^ SHARP to the values shown in the below
table.
5. Respectively select the VSM PRESET mode for SOFT and
STANDARD, and make similar adjustment as in 3 above.
"""" VSM PRESET
Preset mode
BRIGHTBRIGHTSTANDARDSOFT
TINT**Setting Item
COLOUR**TINT+15
?
BRIGHT**?
CONT.**COLOUR+15
??
SHARP**
BRIGHT+15
/ :SELECT??
- / + : OPERATE DISP : EXITCONT+30+15+13
SHARP+15+12
?
No. 5206927 |